- Welding Procedure Specification (WPS) Code: AWS D1.1 Sheet 1 of 3 Company Name: www.WPSAmerica.com Address: info@WPSAmerica.com, 1 (877) WPS-WELD Identification #: GMAW-DEMO WPS Prequalified: Yes Supporting PQR No.(s): N/A Welding Process: GMAW Process Type: Semi-Automatic Position(s): Flat Base Metal Part I (Material Spec., type or grade).
- Trusted Windows (PC) download WPS Office Spreadsheets 11.2. Virus-free and 100% clean download. Get WPS Office Spreadsheets alternative downloads.
- Welding Procedure Specification (WPS) Code: AWS D1.1 Sheet 1 of 3 Company Name: www.WPSAmerica.com Address: info@WPSAmerica.com, 1 (877) WPS-WELD.
- WPS GHA Medicare Provider Enrollment P.O. Box 8248 Madison, WI. Modifier 24 Fact Sheet. Published on Feb 03 2016, Last Updated on Jul 06 2020.
1, 2016, WPS asks that you include a cover sheet with any corrected claims you submit on paper. This will allow us to process your corrected claim in a more timely manner. Paper corrected claims sent without a cover sheet will be returned to you. For your convenience, we provide a Corrected Claim Cover Sheet. You may also use.
What information should they include?
Sufficient details to enable any competent personto apply the information and produce a weld of acceptable quality. The amount of detail and level of controls specified on a WPS is dependanton the application and criticality of the joint to be welded.
Free Wps Spreadsheet Software
For most applications the information required isgenerally similar to that recorded on a Procedure Qualification Record(PQR) or Welding Procedure Approval Record (WPAR), except that ranges areusually permitted on thicknesses, diameters, welding current, materials,joint types etc.
If a WPS is used in conjunction with approved weldingprocedures then the ranges stated should be in accordance with the approvalranges permitted by the welding procedure.
However careful consideration should be given tothe ranges specified to ensure they are achievable, as the ranges givenby welding procedure standards do not always represent good welding practice. For example welding positions permitted by the welding procedure standardmay not be achievable or practical for certain welding processes or consumables.
EN ISO 15609-1 (formally EN 288 Part 2) European Standard ForWelding Procedure Specifications
EN ISO 15609 Defines the contents of a WeldingProcedure Specification in the form of a list of information that shouldbe recorded. For some applications it may be necessary to supplementor reduce the list. For example only in the case of a procedure requiringheat input control would there be a necessity to quote travel speed orrun-out length for manual processes.
Wps Sheet Fit In One Sheet
ASME IX American Boiler and PressureVessel Code
QW 250 Lists the variables for each welding process,all the variables stated should be addressed. The range permittedby the WPS is dictated by the PQR or PQR’s used to qualify it.
Typical Items That Should Be Recorded On W.P.S:-
Common to all Processes .
- Procedure number
- Process type
- Consumable Size, Type and full Codification.
- Consumable Baking Requirement if applicable
- Parent material grade and spec.
- Thickness range.
- Plate or Pipe, Diameter range
- Welding Position
- Joint Fit Up, Preparation, Cleaning, Dimensions etc.
- Backing Strip, Back Gouging information.
- Pre-Heat (Min Temp and Method)
- Interpass If Required (Maximum Temperature recorded )
- Post Weld Heat Treatment. If Required (Time and Temp)
- Welding Technique (weaving,max run width etc.)
- Arc Energy Limits should be stated if impact tests are requiredor if the material being welded is sensitive to heat input.
Welding Wps Sheets
Specific To Welding Processes | MMA | TIG | MIG MAG FCAW | SUB ARC |
Welding current | yes | yes | yes | yes |
Type of Welding current AC/DC Polarity | yes | yes | yes | yes |
Arc voltage | If Auto | yes | yes | |
Pulse parameters (Pulse time and peak & backgound current) | If Used | If Used | ||
Welding Speed If Mechanised | yes | yes | yes | |
Wire configuration | yes | |||
Shielding gas (comp,flow rate) | yes | yes | ||
Purge gas (comp & flow rate) | If Used | If Used | ||
Tungsten electode Diameter and type. | yes | |||
Nozzle diameter | yes | yes | ||
Type of Flux Codification & Brand Name | yes | |||
Nozzle Stand Off Distance (Distance from tip of nozzle to workpiece). | yes |
Sketches
A sketch of the joint configuration is required whichshould include the basic dimensions of the weld preparation. Someindication of the run sequence is also beneficial, particularly if thecorrect sequence is essential to ensure the properties of the weld aremaintained.
Wps Spreadsheets
Production Sequence
Whilst this is good practice it is not a requirement of either
Non Destructive Testing
A WPS is primarily concerned with welding not N D T, this activity should be covered by separate N D T procedures.
General
WPS' drug prior authorization program supports evidence-based treatment and is intended to optimize the care provided by practitioners to our customers. Drugs subject to prior authorization may have specific safety issues, may require a higher level of care coordination, may compete with other products that offer similar or greater value, or may require specific testing to identify appropriate patients. The prior authorization process gathers information so that a coverage decision can be rendered.
Requests for specialty drugs are reviewed by our partner, Diplomat. Non-specialty drugs that require review are either reviewed by our Pharmacy Benefit Manager, or, in rare instances, WPS.
Additional Information Concerning Specialty Drugs
As noted above, WPS has engaged Diplomat to assist with specialty drug management. Diplomat will review each treatment plan relative to evidence-based guidelines that may include step-therapy protocols. Diplomat will ensure the specialty drug is provided in the most appropriate, cost-effective setting. This includes self-administration or the home setting depending on the situation. Specialty drugs dispensed without proper authorization will not be reimbursed, and the customer can be balance billed.
A provider can initiate a specialty drug authorization by calling Diplomat at 888-515-1357.
- To view coverage policies for specialty drugs, click here.